{ "coverage": [ { "requirement_ids": [ "req_001" ], "source_id": "src_001" } ], "issues": [ "The draft's circular_hole_pattern claim specifies a 70 mm pitch radius on a 120 mm by 80 mm rectangular base. A radius of 70 mm puts holes at +/-70 mm in X/Y from center, outside the base extents of +/-60 mm and +/-40 mm, so the claim is geometrically infeasible for the stated base." ], "item_verdicts": [ { "draft_id": "draft_001", "question": null, "reason_code": "conflict", "verdict": "revise" } ], "verdict": "revise" }