Files
cdsl-cad/backend/live-evals/20260831T104758Z/artifacts/cad_929cd1d8e5d0/documents/requirements-review-v1.json
T
2026-09-01 14:10:23 +08:00

23 lines
603 B
JSON

{
"coverage": [
{
"requirement_ids": [
"req_001"
],
"source_id": "src_001"
}
],
"issues": [
"The draft's circular_hole_pattern claim specifies a 70 mm pitch radius on a 120 mm by 80 mm rectangular base. A radius of 70 mm puts holes at +/-70 mm in X/Y from center, outside the base extents of +/-60 mm and +/-40 mm, so the claim is geometrically infeasible for the stated base."
],
"item_verdicts": [
{
"draft_id": "draft_001",
"question": null,
"reason_code": "conflict",
"verdict": "revise"
}
],
"verdict": "revise"
}