Add optional ambient occlusion and graphics quality presets (#1135)
Thanks @CypherNaught-0x.
This commit is contained in:
@@ -0,0 +1,101 @@
|
||||
# Ambient occlusion
|
||||
|
||||
Enable **Ambient occlusion** in the viewport's **View settings** menu or in
|
||||
**Preferences → Graphics**. It adds soft contact shading at corners, recesses and
|
||||
nearby opaque surfaces. It is off by default, applies immediately, and is saved
|
||||
between runs. The shared **Graphics Preset** selector in both settings surfaces
|
||||
combines AO with the display-quality and supersampling controls from #1319 and #1321:
|
||||
|
||||
| Preset | Ambient occlusion | Display quality | Supersampling |
|
||||
|---|---|---|---|
|
||||
| Performance (default) | Off | Normal | Off (1×) |
|
||||
| Quality | On | Fine | 2×, only while the view is still |
|
||||
| Custom | Your manual combination | Your manual combination | Your manual combination |
|
||||
|
||||
Custom is derived from the current settings, not a third preset that overwrites them.
|
||||
Individual controls remain editable. Selecting a preset applies all three settings
|
||||
immediately; MSAA, ground shadow, projection and visual style stay unchanged.
|
||||
Graphics preferences support Cancel, Apply and Restore Defaults. Adaptive supersampling
|
||||
keeps #1321's 0.25-second settling delay, texture limit and 384 MiB memory cap;
|
||||
the requested 2× may be reduced or skipped when the device cannot accommodate it.
|
||||
|
||||
The control channel and connected MCP clients can use the same command as the UI:
|
||||
|
||||
```json
|
||||
{"command":"view.ambient_occlusion","params":{"enabled":true}}
|
||||
```
|
||||
|
||||
`view.graphics_preset {"preset":"quality"}` (or `"performance"`) selects the preset.
|
||||
|
||||
`ui.prefs {"ambient_occlusion": true}` also sets the preference. The command changes
|
||||
only display preferences, without adding a modelling undo step or moving the camera.
|
||||
|
||||
The GPU viewport uses 32 deterministic hemisphere samples per shaded pixel against
|
||||
an opaque depth prepass (at most 2048 pixels on its longest side). The radius follows
|
||||
model size, and depth-range rejection avoids shadows from distant foreground objects.
|
||||
It supports orthographic and perspective cameras and respects section clipping.
|
||||
Wireframe, transparent bodies, overlays and surface-analysis colours are unaffected.
|
||||
Disabling it skips the depth prepass and sampling and releases the full-size depth map.
|
||||
|
||||
This is screen-space shading: off-screen and hidden surfaces cannot contribute.
|
||||
The software fallback and CPU model snapshots do not apply this GPU effect. Capture
|
||||
the actual window with `ui.screenshot` when reviewing it.
|
||||
|
||||
## Metal startup comparison (2026-10-15)
|
||||
|
||||
On an Apple M3 Pro (18-core GPU, 36 GiB unified memory), macOS 27.0
|
||||
(26A428), both unchanged main `0872eb95` and this branch merged with that
|
||||
revision reproduce the same startup defect: `solidcraft --sample` shows the
|
||||
plate's edges and ground shadow but no opaque faces. AO is disabled on the
|
||||
branch and does not exist on main. Both were built with `--profile ci`, launched
|
||||
separately on Metal with MSAA 4x, and captured at 1200 × 850 logical pixels
|
||||
(2400 × 1700 physical pixels). Their viewport captures are pixel-identical.
|
||||
This establishes that the symptom also exists on main; this PR does not fix it.
|
||||
|
||||
For the AO comparison screenshots and timings below, the display mesh was
|
||||
rebuilt by assigning the sample Plate opacity 0.99 and then restoring it to 1.0
|
||||
(with the same colour, `#a6b0bd`). Measurements use opaque faces, GPU
|
||||
tessellation and the actual native viewport after that rebuild. The screenshots
|
||||
are attached in the review conversation, rather than committed as generated assets.
|
||||
|
||||
## AO-only rendering performance (2026-10-15)
|
||||
|
||||
These measurements predate the combined presets. They isolate AO at Normal
|
||||
tessellation with supersampling off; they are **not** timings for the combined
|
||||
Quality preset, which also requests Fine tessellation and adaptive 2× supersampling.
|
||||
|
||||
Same M3 Pro / macOS machine and `ci` build profile as above (not a release-build
|
||||
claim). Window: 2400 × 1700 physical pixels; model viewport: 1900 × 1312.
|
||||
Orthographic home view, shaded with edges, MSAA 4x, normal display quality,
|
||||
supersampling off, ground shadow on, grid/origin/sketches hidden. The heavier
|
||||
design is a rectangular body pattern of the sample: 5 × 5 plates, X spacing
|
||||
90 mm, Y spacing 60 mm, fitted to the viewport (25 opaque bodies).
|
||||
|
||||
These are **completed render-work milliseconds per frame**, not the UI-only
|
||||
`ui.inspect.frame_ms` or a claimed display FPS. Temporary native instrumentation
|
||||
measured from the beginning of `paint_and_update_textures` through command
|
||||
submission and `device.poll(PollType::wait_indefinitely())`. The renderer's
|
||||
accumulated surface-acquisition/queue-submit timing was subtracted; presentation
|
||||
and UI layout are excluded. This includes CPU render preparation and waiting
|
||||
for GPU completion. Continuous repaint was enabled. Instrumentation was removed
|
||||
from the source after building the measurement binary.
|
||||
|
||||
Each design ran three alternating Performance/Quality pairs: 2 seconds warm-up
|
||||
after each switch, then 3 seconds recorded. No builds ran during measurement.
|
||||
The table pools the recorded frames; p95 exposes variability on this shared
|
||||
desktop. It is a local comparative measurement, not a hardware-independent FPS
|
||||
guarantee or a modelling/recompute benchmark.
|
||||
|
||||
| Design | Preset | Frames | Median render ms | p95 render ms |
|
||||
|---|---|---:|---:|---:|
|
||||
| sample | performance | 1082 | 2.52 | 2.65 |
|
||||
| sample | quality | 1077 | 6.35 | 7.27 |
|
||||
| 25-plates | performance | 1074 | 3.15 | 3.45 |
|
||||
| 25-plates | quality | 1082 | 6.93 | 7.50 |
|
||||
|
||||
Per-trial medians (ms), in chronological order:
|
||||
|
||||
- sample-performance: 2.53, 2.47, 2.53.
|
||||
- sample-quality: 5.82, 4.48, 7.08.
|
||||
- 25-plates-performance: 3.13, 3.16, 3.14.
|
||||
- 25-plates-quality: 6.80, 7.02, 6.95.
|
||||