Raise the largest file SolidCraft opens with a setting or launch flag (#4086) (#7565)

* claim: #4086

* Raise the largest file SolidCraft opens with a setting or launch flag (#4086)

* Translate the file size limit strings

* Size limits: design files are .sc now, .solidcraft still read
This commit is contained in:
raykholo
2026-10-28 16:52:29 +00:00
committed by GitHub
parent 506f79c092
commit dd2e44bb12
21 changed files with 985 additions and 89 deletions
+31
View File
@@ -154,6 +154,37 @@ retain world coordinates. A lost cross-component association refreshed by an old
need an explicit relink or refresh when its source returns. Loading never guesses a numerical
correction. Association records, coordinate arrays and placements are bounded and checked.
## Large files
SolidCraft opens STEP, IGES and the other CAD files it imports up to **512 MB**, and design files
up to **256 MB**. A larger file is refused before it is read, and the message says how to raise
the limit. In the desktop app you can raise both:
- **Preferences › General › Largest file to open** sets each limit in MB, from its default up to
16 GB (16384 MB). It is kept between runs; Restore Defaults on the General page puts back 512 MB
and 256 MB.
- **`--max-file-size SIZE`** at launch (`solidcraft --max-file-size 2GB big-assembly.step`) raises
both limits for that run only, over the preference, without saving anything. SIZE is a number
with MB or GB (`2GB`, `1.5GB`, `1500MB`; 1 GB is 1024 MB), at most 16GB. A size below a default
leaves that limit at its default. A size the app can't read stops it from starting, with the
reason. `solidcraft-cli` takes the same flag with any command.
Before you raise them:
- **Memory:** a file is read whole, and what is built from it is held in memory beside it. Expect
several times the file's size in RAM, more for finely detailed parts, and a long open and a slow
view for an assembly with hundreds of thousands of faces.
- **Saving:** a design keeps the text of a STEP import, compressed, and the design limit applies
to the saved file. An import whose compressed text doesn't fit in a design file is refused when
it is imported, so it never opens and then fails to save; raise the design file limit too, or
open the file with `--max-file-size`, which raises both. Opening that design again needs the
same limits.
- **Web app:** the browser version keeps 512 MB and 256 MB: a browser tab can't hold larger files.
Its Preferences show a note instead of the setting.
The control channel sets the same preference with `ui.prefs {"max_step_file_mb": 2048,
"max_design_file_mb": 1024}`.
## Design properties
**File → Design Properties…** (also under **Document Settings** in the Browser, and on the
+2
View File
@@ -339,6 +339,8 @@ One setting per line, sorted by name. A change that adds a setting adds its own
- `logo_accent` (bool, default false: the application bar's logo in shades of the theme's accent instead of the theme's logo colours)
- `look_at_anim`
- `look_at_speed`
- `max_design_file_mb` (default 256): the largest design file opened, in MB, from the default up to 16384 (16 GB) (Preferences › General › Largest file to open, #4086; a `--max-file-size` launch flag overrides both for that run; the web app keeps the defaults and refuses other values; [large files](book/src/guide/files.md#large-files))
- `max_step_file_mb` (default 512): the largest STEP or import file opened, in MB, from the default up to 16384 (16 GB) (Preferences › General › Largest file to open, #4086; a `--max-file-size` launch flag overrides both for that run; the web app keeps the defaults and refuses other values; [large files](book/src/guide/files.md#large-files))
- `middle_double_click` (`home` (default), `fit`, `off`)
- `msaa`
- `nav` (`fusion`, `solidworks`, `inventor`, `alias`, `blender`, `tinkercad`, `openscad`, `touchpad`)