* claim: #6917 * Tests: the six timing assertions do not depend on the wall clock (#6917) Six tests asserted on the wall clock. Their result depended on how loaded the machine was and not only on the code under test: they passed on an idle machine and failed when the test binaries ran beside each other, which is how the suite runs (`cargo xtask test` starts every test binary at once). CONTRIBUTING.md:196 says it: "Tests run beside each other on a busy machine, so a test must not depend on wall-clock timing." The change is confined to the six test files the issue names: - geom: the tangent chain of a helix is a ratio (750 pieces against 3 000) instead of a limit of 200 ms. - io: the placement budget is spent inside the reader, so the clock is gone. - ui-egui: the classification of many faces is a ratio (900 against 3 600) instead of a limit of 10 s. - engine: the clearance measurement drops its 30 s limit; the boolean that gives up reports itself. - engine: the fillet beside a modelled thread is a ratio (a 1 mm thread against an 8 mm one) instead of a limit of 30 s. - ui-egui: the window frame budget goes from 250 ms to 20 s, the limit #6072 gave its own probe. The helper is the one #649 wrote, copied into the crates that need it, with the noise of a run as a parameter.