The frame title, in all thirteen KiCad frames

Read out of KiCad 10.0.5 (/home/akshay/kicad-reference) on 2026-08-20, ahead of deciding what a shared frameTitle() in designer/src/ui/useDocumentTitle.ts has to satisfy. Nothing here is implemented yet; this is the reading.

Deferred on purpose. Akshay parked the migration on 2026-08-20 until the file manager lands, because the document half of every title is a file name and half the branches below turn on whether that file exists, is writable, or has ever been saved — questions only the file manager can answer. Doing it before then would mean inventing those predicates and redoing them after. This file is the reading, kept so the migration is a write-up rather than a re-read. The [Read Only] / [Unsaved] predicates in note C are the ones that need the file manager; the em dash, the placeholders and the GetName/GetFullName split do not, and could move at any time.

The shape they share

Twelve of the thirteen end the same way:

title += wxT( " — " ) + <Frame Name>
SetTitle( title )

An em dash, U+2014, with one ASCII space either side. Never a hyphen. The document half in front of it is built by each frame, and that is where they differ.

The general form, where a frame uses all of it:

title  = "*"                    if IsContentModified()
title += <document part>
title += " " + "[Read Only]"    if the file is not writable
title += " " + "[Unsaved]"      if the file does not exist yet
title += " — " + <Frame Name>

Note the [...] suffixes carry their own leading space (wxS( " " ) + _( "[Read Only]" )), and * carries none — it butts straight against the name.

The table

# Frame Frame Name Document part Placeholder when empty * [Read Only] [Unsaved] Source
1 PCB Editor PCB Editor fn.GetName() (none — see note A) yes yes yes pcbnew/pcb_edit_frame.cpp:2170-2195
2 Schematic Editor Schematic Editor fn.GetName() + [sheetPath] [no schematic loaded] yes yes yes eeschema/sch_edit_frame.cpp:1819-1861
3 Symbol Editor Symbol Editor UnescapeString( LibId.Format() ), or m_reference [no symbol loaded] yes [Read Only Library] — eeschema/symbol_editor/symbol_editor.cpp:58-87
4 Footprint Editor Footprint Editor FPID.Format(), or reference (see note D) [no footprint loaded] yes yes yes pcbnew/footprint_edit_frame.cpp:1080-1132
5 Footprint Library Browser Footprint Library Browser nickname — <full URI> [no library selected] — — — pcbnew/footprint_viewer_frame.cpp:979-999
6 Symbol Library Browser Symbol Library Browser GetFullURI( row, true ) [no library selected] — — — eeschema/symbol_viewer_frame.cpp:1043-1057
7 SPICE Simulator SPICE Simulator filename.GetName() (none — see note A) yes yes yes eeschema/sim/simulator_frame.cpp:316-343
8 Drawing Sheet Editor Drawing Sheet Editor file.GetName() [no drawing sheet loaded] yes — — pagelayout_editor/pl_editor_frame.cpp:570-587
9 Gerber Viewer Gerber Viewer filename.GetFullName() + (with X2 attributes) (see note B) — — — gerbview/gerbview_frame.cpp:660-692
10 Image Converter Image Converter filename.GetFullName() (see note B) — — — bitmap2component/bitmap2cmp_frame.cpp:352-364
11 KiCad (manager) KiCad <major.minor> fn.GetName() [no project loaded] — yes — kicad/kicad_manager_frame.cpp:1292-1312
12 3D Viewer (child) — 3D Viewer — <footprint name> — — — — pcbnew/footprint_viewer_frame.cpp:966, footprint_chooser_frame.cpp:392-398
13 Calculator Tools — fixed string, no dash at all — — — — pcb_calculator/pcb_calculator_frame.cpp:240

The details a shared helper must get right

A. GetName() versus GetFullName()

wxFileName::GetName() is the base name without the extension; GetFullName() is base plus extension. Nine frames use GetName(). Exactly two use GetFullName() — Gerber Viewer (:684) and the Image Converter (:359) — so a helper that always strips the extension is wrong for both, and a helper that never strips it is wrong for the other nine. It has to be a parameter.

useDocumentTitle.ts:67-77's existing frameTitleName() implements GetName() only, and is used by exactly one launcher (the drawing sheet editor).

B. The empty state is not uniform, and this is where ours is broken

Three different behaviours:

  • Bracketed placeholder, dash still appended — frames 2, 3, 4, 5, 6, 8, 11. "[no schematic loaded] — Schematic Editor".
  • Frame name alone, no dash and no placeholder — frames 9 and 10. GerbView runs SetTitle( _( "Gerber Viewer" ) ) as a single string at gerbview_frame.cpp:667; the Image Converter builds the " — " inside if( !m_srcFileName.IsEmpty() ) at :357-360, so an empty converter reads just Image Converter.
  • No empty branch at all — frames 1 and 7 always have a file name, empty or not, and lean on [Unsaved] to say so.

Ours prints Gerber Viewer - Gerber Viewer because the call site passes the frame name as the placeholder and then appends the frame name again. Upstream has no placeholder here to pass.

C. The suffixes are not one set

  • [Read Only] — frames 1, 2, 4, 7, 11.
  • [Read Only Library] — frame 3 only. A different string, on a library rather than a file (symbol_editor.cpp:78-79).
  • [Unsaved] — frames 1, 2, 4, 7.
  • [from schematic] — frame 3 only, on a symbol opened from a schematic (symbol_editor.cpp:66).
  • [from <project>.kicad_pcb] — frame 4 only, on a footprint opened from the board rather than a library. The project name and the extension are interpolated: wxString::Format( _( "[from %s]" ), Prj().GetProjectName() + "." + FILEEXT::PcbFileExtension ) (footprint_edit_frame.cpp:1092-1094). In that branch the document part is the footprint's reference, not its FPID.
  • [<sheetPath>] — frame 2 only, and only when the human-readable sheet path differs from the file name (sch_edit_frame.cpp:1844-1847).

The predicates differ too, and are worth copying rather than guessing:

  • PCB (:2174-2178): readOnly = !fn.IsFileWritable() when fn.IsOk() && fn.FileExists(), else unsaved = true. The two are mutually exclusive.
  • Schematic (:1824-1829): same shape, but readOnly = screen->IsReadOnly() and the existence test is screen->FileExists().
  • Simulator (:317-328): same shape again, over the workbook file.
  • Footprint editor (:1100-1122): not mutually exclusive by file state — [Read Only] on a saved footprint whose library is not writable, [Unsaved] on a footprint whose library item name is empty. Two different branches.
  • Manager (:1300-1301): Prj().IsReadOnly(), and no unsaved case.

D. The footprint editor has four branches, not two

Worth spelling out because it is the most-branched of the thirteen (footprint_edit_frame.cpp:1080-1132):

  1. footprint came from the board → * + reference + [from <project>.kicad_pcb]
  2. footprint came from a library → * + FPID.Format() + [Read Only] if the library is not writable
  3. footprint has a library item name but no valid FPID → * + FPID.GetLibItemName() + [Unsaved], unconditionally
  4. nothing loaded → [no footprint loaded]

E. Where the * goes

Always first, always with no space after it: wxT( "*" ) then += name. Frames 1, 2, 3, 4, 8. The simulator writes it as wxT( "*" ) + filename.GetName() in one expression (:330) but the result is identical.

F. Two frames are not this pattern at all

pcb_calculator_frame.cpp:240 sets a fixed _( "Calculator Tools" ) with no document and no dash. The 3D viewer child frame builds _( "3D Viewer" ) + " — " + <footprint name> — the frame name comes first there, which is the reverse of every other frame — and its standalone form is a bare _( "3D Viewer" ) (eda_3d_viewer_frame.cpp:634).

What ours does today

FRAME_TITLE_SEPARATOR (—) and frameTitleName() exist in designer/src/ui/useDocumentTitle.ts and two call sites use them, both in the drawing sheet editor. Six launchers hand-roll an ASCII hyphen instead:

editors/pcb/PcbEditor.tsx:7515             &nbsp;-&nbsp;PCB Editor
editors/pcb/PcbEditor.tsx:8302             &nbsp;-&nbsp;3D Viewer
editors/gerbview/GerberViewer.tsx:925      &nbsp;-&nbsp;Gerber Viewer
editors/schematic/SchematicEditor.tsx:7214 &nbsp;-&nbsp;Schematic Editor
editors/symbol/SymbolEditor.tsx:1696       &nbsp;-&nbsp;Symbol Editor
editors/footprint/FootprintEditor.tsx:1136 &nbsp;-&nbsp;Footprint Editor

None of the six renders *, [Read Only] or [Unsaved], and the PCB editor's document part strips .kicad_pcb with a regex of its own (PcbEditor.tsx:7513) rather than through frameTitleName.

Gerber Viewer additionally uses projectName as its document part, which is the wrong value entirely: GerbView's title is the active layer's gerber file name (gerbview_frame.cpp:661, 684), and has nothing to do with a project.