// SPDX-License-Identifier: GPL-3.0-or-later
// Copyright (C) 2026 ZiroEDA and contributors.
// Portions derived from KiCad, copyright The KiCad Developers. See NOTICE.md.
/**
* `UNIT_BINDER` — one numeric entry that follows the frame's display unit.
*
* Counterparts:
* - `UNIT_BINDER` (common/widgets/unit_binder.cpp) — the ctor takes
* `( aParent, aLabel, aValueCtrl, aUnitLabel )` where `aParent` is the
* frame acting as `UNITS_PROVIDER`, so the control, its label and the
* little unit word beside it are one object that re-reads and re-labels
* itself whenever the frame's unit changes.
* - `EDA_UNIT_UTILS::UI::ToUserUnit` / `FromUserUnit` / `StringFromValue` /
* `DoubleValueFromString` and `EDA_UNIT_UTILS::GetText` / `GetLabel`
* (common/eda_units.cpp).
*
* It lives here, not in an editor, for the same reason it lives in
* `common/widgets/` upstream: every dialog with a distance in it wants one.
* `status_format.ts` next door is the *other* half of `eda_units.cpp` — the
* low-precision `MessageTextFromValue` a status bar and a message panel print.
* This file is the high-precision `StringFromValue` an editable field needs,
* which is why the two format the same number differently: a status bar shows
* `X 984.2519`, the field the user types into shows `984.25197`.
*
* Everything here is a pure function over (value, unit, range). The React
* field that draws them is `UnitField.tsx`; keeping the arithmetic out of it
* is what lets the numbers be tested without a DOM.
*/
import { EDA_ANGLE } from '@ziroeda/kimath/src/geometry/eda_angle.js';
import { KiROUND } from '@ziroeda/kimath/src/math/util.js';
import {
DoubleValueFromStringIn,
FromUserUnit,
toUserUnit as iuToUserUnit,
type EdaUnits as EDA_UNITS,
stringFromValue as iuStringFromValue,
} from '../eda_units.js';
import { type EdaIuScale, SCH_IU_PER_MM, drawSheetIUScale } from '../index.js';
import { COORD_TYPES_T, type ORIGIN_TRANSFORMS } from '../origin_transforms.js';
import type { StatusUnits } from './kistatusbar_format.js';
import { INDETERMINATE_ACTION, INDETERMINATE_STATE } from './ui_common.js';
/**
* `EDA_UNITS`, restricted to the three a drawing frame's toolbar offers. Same
* spelling as the status bar's, so a frame has one unit variable and not two.
*/
export type EdaUnits = StatusUnits;
/**
* `EDA_UNIT_UTILS::GetText( aUnits, DISTANCE )` (common/eda_units.cpp:144).
* The leading space is upstream's and is why `StringFromValue( …, true )`
* reads "10 mm" and not "10mm".
*/
export function unitText(units: EdaUnits): string {
return units === 'mm' ? ' mm' : units === 'in' ? ' in' : ' mils';
}
/**
* `EDA_UNIT_UTILS::GetLabel` (:180) — `GetText` with the leading space
* trimmed. This is the word `UNIT_BINDER` writes into its unit static text
* (unit_binder.cpp:109-110), i.e. what replaces the hardcoded "mm".
*/
export function unitLabel(units: EdaUnits): string {
return unitText(units).trimStart();
}
/**
* `EDA_UNIT_UTILS::UI::ToUserUnit` (:300) for a value already in millimetres.
*
* Upstream divides internal units by `IU_PER_MILS` (which is
* `IU_PER_MM * 0.0254`), so the scale cancels and the conversion is the same
* for every application: this is that expression with the scale divided out.
*/
export function toUserUnit(units: EdaUnits, mm: number): number {
return units === 'mm' ? mm : units === 'mils' ? mm / 0.0254 : mm / 0.0254 / 1000;
}
/** `EDA_UNIT_UTILS::UI::FromUserUnit` (:296), back to millimetres. */
export function fromUserUnit(units: EdaUnits, value: number): number {
return units === 'mm' ? value : units === 'mils' ? value * 0.0254 : value * 0.0254 * 1000;
}
/**
* `removeTrailingZeros` (common/eda_units.cpp:32) — strip trailing zeros, and
* the decimal separator too if that is all that is left before it.
*/
function removeTrailingZeros(text: string): string {
let len = text.length;
let removeLast = 0;
while (--len > 0 && text[len] === '0') removeLast++;
if (len >= 0 && (text[len] === '.' || text[len] === ',')) removeLast++;
return text.slice(0, text.length - removeLast);
}
/**
* `EDA_UNIT_UTILS::UI::StringFromValue` (:323) for a millimetre value.
*
* The digit counts are upstream's, and they are per-unit rather than uniform:
* mils `%.5f`, inch `%.8f`, mm `%.10f`, each then stripped of trailing zeros.
* `is_eeschema` (`IU_PER_MM == SCH_IU_PER_MM`) drops mils to `%.3f` and inch
* to `%.6f`; the drawing sheet counts microns, so it takes the long form and
* 25 mm shows as `984.25197` mils, exactly as a live `pl_editor` does.
*
* `toFixed` and glibc's `%.*f` can only disagree on an exact tie, which a unit
* conversion of a decimal value does not produce.
*/
export function stringFromValue(
mm: number,
units: EdaUnits,
addUnitsText = false,
iuScale: EdaIuScale = drawSheetIUScale,
): string {
const shortForm = iuScale.IU_PER_MM === SCH_IU_PER_MM;
const value = toUserUnit(units, mm);
const digits = units === 'mils' ? (shortForm ? 3 : 5) : units === 'in' ? (shortForm ? 6 : 8) : 10;
let text = removeTrailingZeros(value.toFixed(digits));
// A non-zero value that rounded away to nothing is re-printed at full
// precision rather than shown as "0".
if (value !== 0 && (text === '0' || text === '-0')) text = removeTrailingZeros(value.toFixed(10));
return addUnitsText ? text + unitText(units) : text;
}
/**
* `EDA_UNIT_UTILS::UI::DoubleValueFromString` (:430) followed by
* `FromUserUnit`, i.e. what `UNIT_BINDER::GetValue()` reads out of the control.
*
* Three details of it are load-bearing and none of them is `Number()`:
* - only the LEADING numeric run is parsed, so "12abc" is 12 and — the case
* this exists for — an EMPTY field is 0, not "leave the model alone";
* - a trailing unit designator overrides the display unit, so "1.5mm" typed
* into a field showing mils means 1.5 mm;
* - the result is quantised to the frame's internal unit, because upstream
* assigns `toMM( binder.GetIntValue() )` and `GetIntValue()` is integer IU.
* That quantisation is what makes mm → mils → mm round-trip exactly instead
* of drifting by the display rounding.
*/
export function parseUnitValue(
text: string,
units: EdaUnits,
iuScale: EdaIuScale = drawSheetIUScale,
): number {
return iuScale.iuToMM(iuScale.mmToIU(parseUnitValueDouble(text, units)));
}
/**
* `UNIT_BINDER::GetDoubleValue()` (unit_binder.cpp:262-291) — the SAME parse
* without the integer quantisation, because that overload returns a `double`
* and its only rounding is `setPrecision( …, false )`, a no-op unless the
* binder was given a precision.
*
* Which of the two a caller wants is not a detail: `DIALOG_GRID_SETTINGS` reads
* `m_gridSizeX.GetDoubleValue()` (`dialog_grid_settings.cpp:80`), so `2` typed
* into a mils field is stored as exactly 0.0508 mm. Quantising it to the
* drawing sheet's microns first would store 0.051 and print the grid back as
* `2.01 mils` — a value the user never typed.
*/
export function parseUnitValueDouble(text: string, units: EdaUnits): number {
const buf = text.trim().replace(/,/g, '.');
let brk = 0;
while (brk < buf.length) {
const ch = buf[brk] as string;
if (!((ch >= '0' && ch <= '9') || ch === '.' || ch === '-' || ch === '+')) break;
brk++;
}
const parsed = Number.parseFloat(buf.slice(0, brk));
const value = Number.isFinite(parsed) ? parsed : 0;
// The 2-significant-character unit designator, lower-cased, as upstream
// reads it. "mi"/"th" are mils/thou, "in" and a double quote are inches.
const designator = buf.slice(brk).trimStart().slice(0, 2).toLowerCase();
let entered = units;
if (designator === 'mm') entered = 'mm';
else if (designator === 'mi' || designator === 'th') entered = 'mils';
else if (designator === 'in' || designator.startsWith('"')) entered = 'in';
return fromUserUnit(entered, value);
}
/**
* `valueDescriptionFromLabel` (unit_binder.cpp:356) — the field's own label
* with its trailing colon removed, which is what the error message names.
*/
export function valueDescriptionFromLabel(label: string): string {
return label.endsWith(':') ? label.slice(0, -1) : label;
}
/** A field's permitted range, in millimetres, as `validateMM` expresses it. */
export interface UnitRange {
/** `aMin`, inclusive. */
min: number;
/** `aMax`, inclusive. */
max: number;
}
/**
* `UNIT_BINDER::Validate( aMin, aMax, EDA_UNITS::MM )` (unit_binder.cpp:375),
* which `pagelayout_editor`'s `validateMM` (properties_frame.cpp:175-178)
* wraps: the limits are always written in millimetres even though the field
* is showing whatever unit the frame is in.
*
* Returns the error message, or `null` when the value is in range. The
* comparison is done in integer internal units on the left and exact internal
* units on the right, exactly as upstream compares `GetValue()` against
* `FromUserUnit( scale, MM, aMin )`.
*
* The message quotes the LIMIT in the display unit — "must be less than
* 393.70079 mils" for the 10 mm pen-width cap when the frame is in mils — so
* the number it names is one the user could type back into the field.
*/
export function validateUnitValue(
label: string,
mm: number,
range: UnitRange,
units: EdaUnits,
iuScale: EdaIuScale = drawSheetIUScale,
): string | null {
const value = iuScale.mmToIU(mm);
const desc = valueDescriptionFromLabel(label);
if (value < range.min * iuScale.IU_PER_MM)
return `${desc} must be at least ${stringFromValue(range.min, units, true, iuScale)}.`;
if (value > range.max * iuScale.IU_PER_MM)
return `${desc} must be less than ${stringFromValue(range.max, units, true, iuScale)}.`;
return null;
}
// ---- UNIT_BINDER, the engine half -------------------------------------------
/** What a `UNIT_BINDER` asks its parent: `UNITS_PROVIDER`'s two answers. */
export interface UNIT_BINDER_UNITS_PROVIDER {
GetUserUnits(): EDA_UNITS;
GetIuScale(): EdaIuScale;
/**
* `m_originTransforms` (`m_units_provider->GetOriginTransforms()`): a frame
* with a display origin answers; a drawing-sheet frame has none, which reads
* as the base class's identity transform.
*/
GetOriginTransforms?(): ORIGIN_TRANSFORMS;
}
/**
* `UNIT_BINDER` (common/widgets/unit_binder.cpp) as a dialog's engine holds
* it: the text in its `wxTextCtrl`, the label an error names, and whether it
* is shown. Every read converts in the parent's CURRENT units, as upstream
* reads `m_units` that `onUnitsChanged` keeps in step. No NUMERIC_EVALUATOR
* yet: an expression reads as its leading number, as
* `DIALOG_DRAW_LAYERS_SETTINGS` already notes.
*/
export class UNIT_BINDER {
private readonly m_unitsProvider: UNIT_BINDER_UNITS_PROVIDER;
/** `m_label->GetLabel()`: what an error message names. */
private m_label: string;
/** `m_units` after a `SetUnits( aUnits )`; null while it follows the parent's. */
private m_unitsOverride: EDA_UNITS | null = null;
/** `m_coordType`, set by `SetCoordType`. */
private m_coordType: COORD_TYPES_T = COORD_TYPES_T.NOT_A_COORD;
/** Where `delayedFocusHandler`'s `DisplayError` goes. */
private readonly m_errorSink: ((aMessage: string) => void) | null;
/** The `wxTextCtrl`'s text. */
private m_value = '';
private m_shown = true;
private m_enabled = true;
/** The wxComboBox's option values, IU (SetOptionsList). */
private m_options: number[] = [];
/** `m_precision`, 0 to 6; 0 or 1 leaves values untruncated. */
private m_precision = 0;
private m_errorMessage = '';
constructor(
aUnitsProvider: UNIT_BINDER_UNITS_PROVIDER,
aLabel: string,
aErrorSink: ((aMessage: string) => void) | null = null,
) {
this.m_unitsProvider = aUnitsProvider;
this.m_label = aLabel;
this.m_errorSink = aErrorSink;
}
GetLabel(): string {
return this.m_label;
}
/** `SetLabel( aLabel )` (`unit_binder.cpp:691`): the label's text, which an error names. */
SetLabel(aLabel: string): void {
this.m_label = aLabel;
}
/** `m_units`: the parent's, read live, until `SetUnits` states another. */
GetUnits(): EDA_UNITS {
return this.m_unitsOverride ?? this.m_unitsProvider.GetUserUnits();
}
/** `SetUnits( aUnits )` (`:159`): `m_units`, and so the label beside the entry. */
SetUnits(aUnits: EDA_UNITS): void {
this.m_unitsOverride = aUnits;
}
/** `SetPrecision( aLength )` (`:171`): the mantissa digits a value is truncated to. */
SetPrecision(aLength: number): void {
this.m_precision = Math.min(aLength, 6);
}
/**
* `setPrecision( aValue, false )` (`:583-600`): truncated - `int64_t tmp = …` cuts toward
* zero - to `m_precision` digits in user units, when that is more than one.
*/
private setPrecision(aValue: number): number {
if (this.m_precision <= 1) return aValue;
const scale = 10 ** this.m_precision;
const iuScale = this.m_unitsProvider.GetIuScale();
const units = this.GetUnits();
const tmp = Math.trunc(iuToUserUnit(iuScale, units, aValue) * scale);
return FromUserUnit(iuScale, units, tmp / scale);
}
/** `SetCoordType( aCoordType )`: how `m_originTransforms` treats the value. */
SetCoordType(aCoordType: COORD_TYPES_T): void {
this.m_coordType = aCoordType;
}
/** `m_originTransforms.ToDisplay( aValue, m_coordType )`; identity with no display origin. */
private toDisplay(aValue: number): number {
const ot = this.m_unitsProvider.GetOriginTransforms?.();
return ot ? ot.ToDisplay(aValue, this.m_coordType) : aValue;
}
/** `m_originTransforms.FromDisplay( aValue, m_coordType )`. */
private fromDisplay(aValue: number): number {
const ot = this.m_unitsProvider.GetOriginTransforms?.();
return ot ? ot.FromDisplay(aValue, this.m_coordType) : aValue;
}
/**
* `SetDoubleValue( aValue )` (`unit_binder.cpp:434-444`): IU into the field,
* through the display origin (`getTextForDoubleValue`), no unit label.
*/
SetDoubleValue(aValue: number): void {
this.m_value = this.getTextForDoubleValue(aValue);
}
/** `getTextForDoubleValue( aValue )` (`:495-505`): IU to the field's text, no unit label. */
private getTextForDoubleValue(aValue: number): string {
return iuStringFromValue(
this.m_unitsProvider.GetIuScale(),
this.GetUnits(),
this.setPrecision(this.toDisplay(aValue)),
false,
);
}
/**
* `SetOptionsList( aOptions )` (`:640-649`): a wxComboBox's list, each value through
* getTextForValue. The values are kept and formatted when asked, which is the re-fill
* `onUnitsChanged` does (`:205-214`) when the frame's units change.
*/
SetOptionsList(aOptions: readonly number[]): void {
this.m_options = [...aOptions];
}
/** The combo's strings, in the current units. */
GetOptionsList(): string[] {
return this.m_options.map((v) => this.getTextForDoubleValue(v));
}
/** `SetValue( long long )`. */
SetValue(aValue: number): void {
this.SetDoubleValue(aValue);
}
/** `ChangeValue( int )`: as `SetValue`; there is no change event to withhold here. */
ChangeValue(aValue: number): void {
this.SetDoubleValue(aValue);
}
/** `ChangeDoubleValue( aValue )` (`:514`): as `SetDoubleValue`, with no change event. */
ChangeDoubleValue(aValue: number): void {
this.SetDoubleValue(aValue);
}
/** `ChangeAngleValue( aValue )` (`:520`): as `SetAngleValue`, with no change event. */
ChangeAngleValue(aValue: EDA_ANGLE): void {
this.SetAngleValue(aValue);
}
/** `IsNull()` (`:675`): the entry is empty. */
IsNull(): boolean {
return this.m_value === '';
}
/** `SetNull()` (`:684`): empty the entry. */
SetNull(): void {
this.m_value = '';
}
/**
* `SetAngleValue( aValue )` (`:447`):
* `SetDoubleValue( m_originTransforms.ToDisplay( aValue, m_coordType ) )` -
* which takes the display origin a second time, as upstream does.
*/
SetAngleValue(aValue: EDA_ANGLE): void {
const ot = this.m_unitsProvider.GetOriginTransforms?.();
this.SetDoubleValue(ot ? ot.ToDisplay(aValue, this.m_coordType) : aValue.AsDegrees());
}
/** The field's text, as the control holds it. */
GetText(): string {
return this.m_value;
}
/** The user typing into the control. */
SetText(aText: string): void {
this.m_value = aText;
}
/** `GetDoubleValue()`: the text in the parent's units, to IU, out of the display origin. */
GetDoubleValue(): number {
return this.fromDisplay(
this.setPrecision(
DoubleValueFromStringIn(this.m_unitsProvider.GetIuScale(), this.GetUnits(), this.m_value),
),
);
}
/**
* `GetAngleValue()` (`:634`):
* `m_originTransforms.FromDisplay( EDA_ANGLE( GetDoubleValue(), DEGREES_T ), m_coordType )`.
*/
GetAngleValue(): EDA_ANGLE {
const ot = this.m_unitsProvider.GetOriginTransforms?.();
const angle = new EDA_ANGLE(this.GetDoubleValue());
return ot ? ot.FromDisplay(angle, this.m_coordType) : angle;
}
/** `GetValue()` (`:554-600`): `ValueFromString`, `KiROUND` to IU. */
GetValue(): number {
return KiROUND(this.GetDoubleValue());
}
/** `GetIntValue()`: `(int) GetValue()`. */
GetIntValue(): number {
return Math.trunc(this.GetValue());
}
/** `IsIndeterminate()`: the entry holds "-- mixed values --" or "-- leave unchanged --". */
IsIndeterminate(): boolean {
const text = this.GetText();
return text === INDETERMINATE_STATE || text === INDETERMINATE_ACTION;
}
/**
* `Validate( aMin, aMax, aUnits )` (`:375-419`). Out of range, the message
* names the limit in the field's own unit, and `delayedFocusHandler` shows it
* - here straight to the sink, the page's modal.
*/
Validate(aMin: number, aMax: number, aUnits: EDA_UNITS): boolean {
// An indeterminate field ("-- leave unchanged --", "<...>") has no value to range-check.
if (this.IsIndeterminate()) return true;
const scale = this.m_unitsProvider.GetIuScale();
const desc = valueDescriptionFromLabel(this.m_label);
const fail = (aWhat: string, aLimitIU: number): boolean => {
const limit = iuStringFromValue(scale, this.GetUnits(), aLimitIU, true);
this.m_errorMessage = `${desc} must be ${aWhat} ${limit}.`;
this.m_errorSink?.(this.m_errorMessage);
return false;
};
if (this.GetValue() < FromUserUnit(scale, aUnits, aMin))
return fail('at least', FromUserUnit(scale, aUnits, aMin));
if (this.GetValue() > FromUserUnit(scale, aUnits, aMax))
return fail('less than', FromUserUnit(scale, aUnits, aMax));
return true;
}
/** The last message `Validate` raised. */
GetErrorMessage(): string {
return this.m_errorMessage;
}
/** `Show( aShow )`: the label, the control and the units together. */
Show(aShow: boolean): void {
this.m_shown = aShow;
}
IsShown(): boolean {
return this.m_shown;
}
/** `Enable( aEnable )` (`:697`): the label, the control and the units together. */
Enable(aEnable: boolean): void {
this.m_enabled = aEnable;
}
/** `m_valueCtrl->IsEnabled()`. */
IsEnabled(): boolean {
return this.m_enabled;
}
}